The Control/Section Test lets you test the functionality of your section outputs. You can use this test to check the performance of your sections, including spray pattern, throughout the operating range of your control valve.
To get to the diagnostic tests for RCM, tap the Diagnostics button. Then tap the Tests tab. Turn off the Master Switch to access the test drop-down list. Select the test from the list, and then tap the Begin button.
Read the warning and take necessary precautions before starting the test. Acknowledge the warning when ready.
Turn on the sections you wish to test. Turn on your Master Switch and then tap the Start button. Use the adjustment buttons to operate the control valve. Now you can inspect and diagnose the performance of the sections. You can also turn sections on and off as needed during your testing.
Tap the Accept button to stop the test.